logo

Auger

What Is Auger Electron Spectroscopy?

AES is an electron-beam-based surface analysis method. It detects Auger electrons emitted from the surface after excitation, enabling identification of elements in the top few nanometers of a material. Because the analysis depth is extremely shallow, AES is ideal for studying surface chemistry that strongly affects performance, reliability, adhesion, corrosion resistance, and device behavior.

What AES Measures

AES is primarily used for:

  • Surface elemental composition (top few nanometers)

  • Micro-area analysis on small regions or localized defects

  • Elemental mapping to visualize distributions across a surface

  • Depth profiling (with ion sputtering) to evaluate composition vs. depth in thin films and multilayers

Best suited for: conductive materials and many semi-conductive systems.
(Non-conductive samples may require specific preparation or alternative methods depending on charging behavior.)

Why Use AES?

AES is chosen when you need:

  • True surface sensitivity (not bulk-averaged results)

  • High spatial resolution for small features, particles, or localized defects

  • Thin film and interface evaluation, including layer structure and diffusion (with depth profiling)

AES often answers questions like:

  • What contaminant is present at the failure site?

  • Is there oxidation, corrosion products, or surface residues?

  • Is a coating or thin film uniform across a defect region?

  • Do elements segregate at grain boundaries or interfaces?

  • What changes in composition occur across film thickness?

Typical Application Scenarios

Contamination & Cleanliness Verification

  • Identify unknown surface residues, films, or deposits

  • Verify cleaning effectiveness and process contamination sources

  • Determine whether contamination is organic/inorganic via complementary methods

Adhesion & Delamination Investigations

  • Study surfaces after delamination to determine failure mode

  • Detect interfacial contaminants that reduce bonding strength

  • Compare “good vs. bad” samples to locate chemistry differences

Thin Films & Coatings

  • Elemental composition of thin films and coatings

  • Interface evaluation and diffusion across layers (depth profiling)

  • Surface oxidation and passivation layer assessment

Microelectronics & Semiconductor Materials

  • Localized analysis of small structures and regions

  • Composition verification for conductive films and metallization

  • Defect-focused surface investigations

Corrosion & Oxidation

  • Characterize corrosion products and oxidation layers

  • Determine surface enrichment or depletion of alloying elements

  • Support root-cause analysis for corrosion failures

Surface vs. Depth Information

Surface analysis (AES):
Measures elemental composition in the outermost surface region.

Depth profiling (AES + sputtering):
Measures how composition changes with depth, useful for:

  • multilayer films

  • diffusion studies

  • coatings and oxides

  • interfacial chemistry changes

Xinbodi selects the depth profiling approach based on film thickness, expected interfaces, and required detection sensitivity.

Sample Types & Considerations

AES is commonly used for:

  • metals and alloys

  • conductive coatings and thin films

  • semiconductor-related conductive layers

  • corrosion layers and surface treatments

Key project factors:

  • analysis area size

  • surface condition (roughness, oxidation, residues)

  • whether destructive testing (sputtering) is allowed

  • availability of “good vs. bad” comparisons

What You Will Receive

Each Auger project is delivered with a clear, structured report designed to support engineering decisions. A typical deliverable includes:

  • Project objective and sample description

  • Test plan and analysis conditions

  • Surface elemental results with interpretation

  • Elemental maps (when applicable)

  • Depth profile plots (when applicable)

  • Comparison summary (good vs. bad, supplier A vs. B, region-to-region)

  • Conclusions and recommended next steps
    (e.g., confirmatory tests, process changes, cleaning improvements)

Why Choose Xinbodi for Auger (AES)?

  • Strong expertise in surface-sensitive investigation and failure analysis

  • Ability to analyze small features and localized defects

  • Clear interpretation focused on root cause and corrective action

  • Multi-technique support (AES + XPS/TOF-SIMS/SEM-EDS/FTIR, as needed)

  • Confidential handling of proprietary materials and IP-sensitive projects

FAQs

Both are surface-sensitive techniques. XPS provides elemental and chemical-state information and works well for most materials. AES often offers better spatial resolution for micro-area analysis and is commonly applied to conductive materials and localized defects.

AES is primarily elemental. For detailed organic chemistry identification, Xinbodi may recommend complementary methods such as FTIR or TOF-SIMS, depending on the question.

Standard AES surface measurement is minimally invasive. Depth profiling requires sputtering and is considered destructive to the analyzed area.

Charging behavior can limit AES on non-conductive samples. Xinbodi can evaluate feasibility and suggest alternatives (e.g., XPS, TOF-SIMS) if needed.

Have additional questions?