logo

TGA

What is TGA?

TGA (Thermogravimetric Analysis) is a thermal analysis technique that measures a sample’s mass change as a function of temperature and/or time under a controlled atmosphere. By tracking weight loss (or gain), TGA reveals information about moisture/volatile content, thermal stability, decomposition behavior, oxidation, and residue/ash content.

TGA is widely used for polymers, composites, coatings, adhesives, pharmaceuticals, inorganic powders, ceramics, and battery materials to support material identification, QC, and thermal reliability evaluation.

What TGA Can Help You Solve

  • Thermal stability screening (decomposition onset and stability window)

  • Moisture and volatile content measurement (drying loss, solvent residue)

  • Composition estimation (organic vs inorganic fraction; filler/ash/residue content)

  • Oxidation behavior under air/oxygen (oxidation onset, burn-off steps)

  • Material comparison (lot-to-lot, supplier comparison, before/after aging)

  • Process troubleshooting (unexpected mass loss stages, contamination, incomplete cure)

Typical Applications

  • Polymers & composites: degradation steps, filler/ash content, oxidative stability comparison

  • Adhesives/coatings/resins: residual solvent/volatiles, curing-related stability checks

  • Inorganic powders & ceramics: dehydration, decomposition (e.g., carbonates), residue behavior

  • Battery & energy materials: binder burn-off, thermal stability screening (project-dependent)

  • Pharmaceuticals & chemicals: moisture/solvent content and decomposition profile (project-dependent)

  • General QC: incoming material verification by characteristic weight-loss fingerprints

Test Capabilities & What You Receive

Core Outputs

  • TG curve: mass (%) vs temperature/time

  • DTG (optional): derivative mass loss rate vs temperature (helps separate overlapping steps)

Key Parameters (commonly reported)

  • Onset temperature of mass loss / decomposition

  • Stepwise weight loss (%) by temperature range

  • Residual mass / ash (%) at the end temperature

  • Oxidation onset and burn-off behavior (in air/O₂)

Atmospheres & Programs (project-dependent)

  • Inert (N₂/Ar): pyrolysis/decomposition without oxidation

  • Oxidative (air/O₂): oxidation stability and ash determination

  • Custom heating profiles: ramps, isothermal holds, multi-step programs (e.g., inert → air switching)

Deliverables

  • TG/DTG plots (as applicable)

  • Results table with key temperatures and weight-loss/residue values

  • Interpretation notes and comparison summary (optional)

  • Pass/fail vs your specification (if provided)

Sample Requirements

  • Sample types: powders, small solids, films, fibers, cured resins, composites

  • Typical amount: usually 5–30 mg (depends on material and method)

  • Condition: clean, dry, and representative; avoid contamination

  • Safety & compatibility: provide SDS for unknown/hazardous materials; confirm no unstable/explosive samples

  • Information to provide: target temperature range, desired atmosphere, expected composition (if known), and your goal (moisture, residue, stability, comparison, etc.)

Workflow

  • Requirement review (objective, temperature range, atmosphere, acceptance criteria)

  • Method setup (crucible selection, gas flow, heating program)

  • Measurement under controlled conditions

  • Data processing (onset determination, step segmentation, residue calculation)

  • Reporting (plots + key values + conclusions and recommendations)

FAQs

TGA measures mass change; DSC measures heat flow (melting, crystallization, glass transition, etc.). They are complementary and often used together.

  • Nitrogen/argon: shows decomposition without oxidation (pyrolysis).

  • Air/oxygen: shows oxidation stability and burn-off/ash behavior.
    Many projects use both, sometimes with a gas-switch program.

Often yes—residual mass at high temperature (especially after oxidative burn-off) can correlate with inorganic filler/ash fraction. Interpretation depends on material system.

TGA alone does not identify evolved gases. If you need gas identification, we recommend TG-EGA (TG-FTIR / TG-MS / TG-GC/MS).

Results can shift with heating rate, sample mass, pan type, gas flow, and sample preparation. We document conditions and can standardize methods for QC comparability.

Have additional questions?
OR